Помирает диск с корнем
Привет, посоны.
Есть один SSD диск с системой. Смартцтл показывает такое
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0032 100 100 050 Old_age Always - 0
5 Reallocated_Sector_Ct 0x0032 100 100 050 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 050 Old_age Always - 563
12 Power_Cycle_Count 0x0032 100 100 050 Old_age Always - 144
160 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 0
161 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 18515
163 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 20
164 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 421
165 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 600
166 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 2
167 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 78
168 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 0
169 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 100
175 Program_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 268435456
176 Erase_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 4216047
177 Wear_Leveling_Count 0x0032 100 100 050 Old_age Always - 242116
178 Used_Rsvd_Blk_Cnt_Chip 0x0032 100 100 050 Old_age Always - 285212672
в логах вижу страшное
[Thu Apr 16 09:56:21 2026] ata5.00: exception Emask 0x0 SAct 0x80000080 SErr 0x0 action 0x6 frozen
[Thu Apr 16 09:56:21 2026] ata5.00: failed command: READ FPDMA QUEUED
[Thu Apr 16 09:56:21 2026] ata5.00: cmd 60/60:38:28:12:65/00:00:07:00:00/40 tag 7 ncq dma 49152 in
res 40/00:01:00:00:00/00:00:00:00:00/00 Emask 0x4 (timeout)
[Thu Apr 16 09:56:21 2026] ata5.00: status: { DRDY }
[Thu Apr 16 09:56:21 2026] ata5.00: failed command: WRITE FPDMA QUEUED
[Thu Apr 16 09:56:21 2026] ata5.00: cmd 61/38:f8:f0:da:73/00:00:04:00:00/40 tag 31 ncq dma 28672 out
res 40/00:00:00:00:00/00:00:00:00:00/00 Emask 0x4 (timeout)
[Thu Apr 16 09:56:21 2026] ata5.00: status: { DRDY }
[Thu Apr 16 09:56:21 2026] ata5: hard resetting link
[Thu Apr 16 09:56:25 2026] ata5: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[Thu Apr 16 09:56:25 2026] ata5.00: configured for UDMA/133
[Thu Apr 16 09:56:25 2026] sd 4:0:0:0: [sdb] tag#7 FAILED Result: hostbyte=DID_OK driverbyte=DRIVER_OK cmd_age=33s
[Thu Apr 16 09:56:25 2026] sd 4:0:0:0: [sdb] tag#7 Sense Key : Aborted Command [current]
[Thu Apr 16 09:56:25 2026] sd 4:0:0:0: [sdb] tag#7 Add. Sense: No additional sense information
[Thu Apr 16 09:56:25 2026] sd 4:0:0:0: [sdb] tag#7 CDB: Read(10) 28 00 07 65 12 28 00 00 60 00
[Thu Apr 16 09:56:25 2026] I/O error, dev sdb, sector 124064296 op 0x0:(READ) flags 0x80700 phys_seg 12 prio class 2
вопрос заключается в следующем - как правильно перенести систему на новый диск?
Ну вот типа купил я новый диск в ДНС и как дальше мне не больно перенести все данные?